  "id": "03-risk-assessment",
  "title": "AI risk assessment",
  "summary": "A risk record for each of the 17 AI systems in scope, on fixed scales, with its treatment, the risk left after it and who accepted that risk.",
  "synthetic": "Synthetic: an illustrative record, generated from the model of a fictional hospital in a synthetic reference architecture. It holds no customer data and no record of an actual hospital.",
  "claim": "This reference model is designed to support conformity with ISO/IEC 42001:2023.",
  "notice": "Not legal advice: obligation names are short forms, and the act's text governs. No certification or conformity finding; not affiliated with or endorsed by ISO or IEC. Standard numbers and titles are cited from ISO's public preview.",
  "sections": [
    {
      "heading": "Risk criteria",
      "mappedTo": [
        "23894-6.3",
        "23894-Annex-A",
        "23894-Annex-B"
      ],
      "blocks": [
        {
          "kind": "fields",
          "rows": [
            [
              "Likelihood, lowest to highest",
              "rare, unlikely, possible, likely, almost certain"
            ],
            [
              "Consequence, lowest to highest",
              "negligible, minor, moderate, major, severe"
            ],
            [
              "Residual risk, lowest to highest",
              "low, medium, high"
            ],
            [
              "Objectives a risk can bear on",
              "Accountability, AI expertise, Availability and quality of training and test data, Environmental impact, Fairness, Maintainability, Privacy, Robustness, Safety, Security, Transparency and explainability"
            ],
            [
              "Sources a risk can come from",
              "Complexity of environment, Lack of transparency and explainability, Level of automation, Risk sources related to machine learning, System hardware issues, System life cycle issues, Technology readiness"
            ],
            [
              "Assessed on",
              "2026-03-16"
            ]
          ]
        }
      ]
    },
    {
      "heading": "Risk register",
      "mappedTo": [
        "23894-6.4",
        "42001-8.2"
      ],
      "blocks": [
        {
          "kind": "table",
          "columns": [
            "AI system",
            "Likelihood",
            "Consequence",
            "Residual risk",
            "Owner",
            "Accepted by"
          ],
          "rows": [
            [
              "Clinical note drafting",
              "possible",
              "moderate",
              "low",
              "Chief Medical Officer",
              "Chief Medical Officer"
            ],
            [
              "Coding, billing and claims",
              "likely",
              "minor",
              "low",
              "CISO / Compliance Officer",
              "CISO / Compliance Officer"
            ],
            [
              "Deterioration warning",
              "possible",
              "severe",
              "medium",
              "Chief Medical Officer",
              "Hospital Board"
            ],
            [
              "Diagnostic support",
              "possible",
              "major",
              "medium",
              "Chief Medical Officer",
              "Hospital Board"
            ],
            [
              "Emergency triage",
              "possible",
              "severe",
              "medium",
              "Chief Nursing Officer",
              "Hospital Board"
            ],
            [
              "Image analysis",
              "possible",
              "major",
              "medium",
              "Chief Medical Officer",
              "Hospital Board"
            ],
            [
              "Medication checking",
              "unlikely",
              "severe",
              "medium",
              "Chief Medical Officer",
              "Hospital Board"
            ],
            [
              "Nursing acuity and risk scoring",
              "possible",
              "major",
              "medium",
              "Chief Nursing Officer",
              "Hospital Board"
            ],
            [
              "Nursing-quality analytics",
              "possible",
              "minor",
              "low",
              "Chief Nursing Officer",
              "Chief Nursing Officer"
            ],
            [
              "Order-entry decision support",
              "possible",
              "major",
              "medium",
              "Chief Medical Officer",
              "Hospital Board"
            ],
            [
              "Patient digital assistant",
              "possible",
              "moderate",
              "low",
              "CFO / COO",
              "CFO / COO"
            ],
            [
              "Predictive maintenance",
              "possible",
              "moderate",
              "low",
              "CFO / COO",
              "CFO / COO"
            ],
            [
              "Restricted patient service administration",
              "unlikely",
              "major",
              "low",
              "CFO / COO",
              "CFO / COO"
            ],
            [
              "Results prioritisation",
              "unlikely",
              "severe",
              "low",
              "Chief Medical Officer",
              "Chief Medical Officer"
            ],
            [
              "Staff performance monitoring",
              "possible",
              "major",
              "medium",
              "Chief Nursing Officer",
              "Hospital Board"
            ],
            [
              "Staff scheduling and task allocation",
              "possible",
              "major",
              "medium",
              "Chief Nursing Officer",
              "Hospital Board"
            ],
            [
              "Surgical decision support",
              "unlikely",
              "severe",
              "medium",
              "Chief Medical Officer",
              "Hospital Board"
            ]
          ]
        }
      ]
    },
    {
      "heading": "AI risk: Clinical note drafting",
      "mappedTo": [
        "23894-6.4",
        "23894-6.5",
        "42001-8.3",
        "23894-Annex-A",
        "23894-Annex-B"
      ],
      "blocks": [
        {
          "kind": "fields",
          "rows": [
            [
              "AI system",
              "Clinical note drafting"
            ],
            [
              "Human oversight",
              "Human-over-the-loop: review by exception; override always available"
            ],
            [
              "Risk",
              "A drafted note records something the clinician did not say, or leaves out a finding, and is signed unread."
            ],
            [
              "Objectives it bears on",
              "Safety, Accountability"
            ],
            [
              "Where it comes from",
              "Level of automation, Risk sources related to machine learning"
            ],
            [
              "Likelihood",
              "possible"
            ],
            [
              "Consequence",
              "moderate"
            ],
            [
              "Treatment",
              "Drafts stay marked as drafts until a clinician edits and signs them; a sample of signed notes is checked each month."
            ],
            [
              "Treated by",
              "No control of the management system carries it out: it rests on the system's own design and its department's practice, as the run-time controls cover the high-risk uses only."
            ],
            [
              "Residual risk",
              "low"
            ],
            [
              "Owner",
              "Chief Medical Officer"
            ],
            [
              "Residual risk accepted by",
              "Chief Medical Officer"
            ],
            [
              "Accepted on",
              "2026-03-16"
            ]
          ]
        }
      ]
    },
    {
      "heading": "AI risk: Coding, billing and claims",
      "mappedTo": [
        "23894-6.4",
        "23894-6.5",
        "42001-8.3",
        "23894-Annex-A",
        "23894-Annex-B"
      ],
      "blocks": [
        {
          "kind": "fields",
          "rows": [
            [
              "AI system",
              "Coding, billing and claims"
            ],
            [
              "Human oversight",
              "Human-over-the-loop: review by exception; override always available"
            ],
            [
              "Risk",
              "A coding suggestion is wrong and a claim is billed too high or too low."
            ],
            [
              "Objectives it bears on",
              "Accountability"
            ],
            [
              "Where it comes from",
              "Risk sources related to machine learning"
            ],
            [
              "Likelihood",
              "likely"
            ],
            [
              "Consequence",
              "minor"
            ],
            [
              "Treatment",
              "A coder confirms every suggestion before a claim leaves the hospital, more than the review by exception its tier sets as the floor, and a monthly audit samples coded episodes."
            ],
            [
              "Treated by",
              "No control of the management system carries it out: it rests on the system's own design and its department's practice, as the run-time controls cover the high-risk uses only."
            ],
            [
              "Residual risk",
              "low"
            ],
            [
              "Owner",
              "CISO / Compliance Officer"
            ],
            [
              "Residual risk accepted by",
              "CISO / Compliance Officer"
            ],
            [
              "Accepted on",
              "2026-03-16"
            ]
          ]
        }
      ]
    },
    {
      "heading": "AI risk: Deterioration warning",
      "mappedTo": [
        "23894-6.4",
        "23894-6.5",
        "42001-8.3",
        "23894-Annex-A",
        "23894-Annex-B"
      ],
      "blocks": [
        {
          "kind": "fields",
          "rows": [
            [
              "AI system",
              "Deterioration warning"
            ],
            [
              "Human oversight",
              "Human-in-the-loop: a named, competent person reviews each output before it is acted on"
            ],
            [
              "Overseen by",
              "Attending Physician"
            ],
            [
              "Risk",
              "A patient who is getting worse is not flagged in time, or false alarms teach the ward to ignore the warnings."
            ],
            [
              "Objectives it bears on",
              "Safety, Robustness, Availability and quality of training and test data"
            ],
            [
              "Where it comes from",
              "Risk sources related to machine learning, Complexity of environment"
            ],
            [
              "Likelihood",
              "possible"
            ],
            [
              "Consequence",
              "severe"
            ],
            [
              "Treatment",
              "Warnings add to routine observations and never replace them; alarm rates and missed events are reviewed every month."
            ],
            [
              "Treated by",
              "Oversee AI Outputs; Monitor AI Performance and Incidents"
            ],
            [
              "Residual risk",
              "medium"
            ],
            [
              "Owner",
              "Chief Medical Officer"
            ],
            [
              "Residual risk accepted by",
              "Hospital Board"
            ],
            [
              "Accepted on",
              "2026-04-01"
            ]
          ]
        }
      ]
    },
    {
      "heading": "AI risk: Diagnostic support",
      "mappedTo": [
        "23894-6.4",
        "23894-6.5",
        "42001-8.3",
        "23894-Annex-A",
        "23894-Annex-B"
      ],
      "blocks": [
        {
          "kind": "fields",
          "rows": [
            [
              "AI system",
              "Diagnostic support"
            ],
            [
              "Human oversight",
              "Human-in-the-loop: a named, competent person reviews each output before it is acted on"
            ],
            [
              "Overseen by",
              "Radiologist"
            ],
            [
              "Risk",
              "A suggested diagnosis anchors the clinician on the wrong condition."
            ],
            [
              "Objectives it bears on",
              "Safety, Transparency and explainability"
            ],
            [
              "Where it comes from",
              "Lack of transparency and explainability, Risk sources related to machine learning"
            ],
            [
              "Likelihood",
              "possible"
            ],
            [
              "Consequence",
              "major"
            ],
            [
              "Treatment",
              "Each suggestion shows its evidence and its uncertainty, clinicians record their own reasoning, and cases are sampled each quarter."
            ],
            [
              "Treated by",
              "Oversee AI Outputs; Monitor AI Performance and Incidents"
            ],
            [
              "Residual risk",
              "medium"
            ],
            [
              "Owner",
              "Chief Medical Officer"
            ],
            [
              "Residual risk accepted by",
              "Hospital Board"
            ],
            [
              "Accepted on",
              "2026-04-01"
            ]
          ]
        }
      ]
    },
    {
      "heading": "AI risk: Emergency triage",
      "mappedTo": [
        "23894-6.4",
        "23894-6.5",
        "42001-8.3",
        "23894-Annex-A",
        "23894-Annex-B"
      ],
      "blocks": [
        {
          "kind": "fields",
          "rows": [
            [
              "AI system",
              "Emergency triage"
            ],
            [
              "Human oversight",
              "Human-in-the-loop: a named, competent person reviews each output before it is acted on"
            ],
            [
              "Overseen by",
              "Registered Nurse"
            ],
            [
              "Risk",
              "A patient's urgency is rated too low and their care is delayed, more often for older patients and for those who do not speak the local language, whom the supplier's training data holds fewer of."
            ],
            [
              "Objectives it bears on",
              "Safety, Fairness, Availability and quality of training and test data"
            ],
            [
              "Where it comes from",
              "Risk sources related to machine learning, Level of automation"
            ],
            [
              "Likelihood",
              "possible"
            ],
            [
              "Consequence",
              "severe"
            ],
            [
              "Treatment",
              "Triage staff confirm or change every score; under-triage is reviewed weekly for the first three months, then monthly."
            ],
            [
              "Treated by",
              "Oversee AI Outputs; Monitor AI Performance and Incidents"
            ],
            [
              "Residual risk",
              "medium"
            ],
            [
              "Owner",
              "Chief Nursing Officer"
            ],
            [
              "Residual risk accepted by",
              "Hospital Board"
            ],
            [
              "Accepted on",
              "2026-04-01"
            ]
          ]
        }
      ]
    },
    {
      "heading": "AI risk: Image analysis",
      "mappedTo": [
        "23894-6.4",
        "23894-6.5",
        "42001-8.3",
        "23894-Annex-A",
        "23894-Annex-B"
      ],
      "blocks": [
        {
          "kind": "fields",
          "rows": [
            [
              "AI system",
              "Image analysis"
            ],
            [
              "Human oversight",
              "Human-in-the-loop: a named, competent person reviews each output before it is acted on"
            ],
            [
              "Overseen by",
              "Radiologist"
            ],
            [
              "Risk",
              "A missed or false finding on an image delays or misdirects a diagnosis."
            ],
            [
              "Objectives it bears on",
              "Safety, Robustness"
            ],
            [
              "Where it comes from",
              "Risk sources related to machine learning, Lack of transparency and explainability"
            ],
            [
              "Likelihood",
              "possible"
            ],
            [
              "Consequence",
              "major"
            ],
            [
              "Treatment",
              "A specialist still reads every image and the system only flags; disagreement between the two is tracked."
            ],
            [
              "Treated by",
              "Oversee AI Outputs; Monitor AI Performance and Incidents"
            ],
            [
              "Residual risk",
              "medium"
            ],
            [
              "Owner",
              "Chief Medical Officer"
            ],
            [
              "Residual risk accepted by",
              "Hospital Board"
            ],
            [
              "Accepted on",
              "2026-04-01"
            ]
          ]
        }
      ]
    },
    {
      "heading": "AI risk: Medication checking",
      "mappedTo": [
        "23894-6.4",
        "23894-6.5",
        "42001-8.3",
        "23894-Annex-A",
        "23894-Annex-B"
      ],
      "blocks": [
        {
          "kind": "fields",
          "rows": [
            [
              "AI system",
              "Medication checking"
            ],
            [
              "Human oversight",
              "Human-in-the-loop: a named, competent person reviews each output before it is acted on"
            ],
            [
              "Overseen by",
              "Pharmacist"
            ],
            [
              "Risk",
              "A dangerous interaction or dose is not flagged."
            ],
            [
              "Objectives it bears on",
              "Safety"
            ],
            [
              "Where it comes from",
              "System life cycle issues"
            ],
            [
              "Likelihood",
              "unlikely"
            ],
            [
              "Consequence",
              "severe"
            ],
            [
              "Treatment",
              "A pharmacy check still follows every order, and the supplier updates the rule set with each change to the hospital's medicines list, which the hospital sends it."
            ],
            [
              "Treated by",
              "Oversee AI Outputs; Check AI Input Data"
            ],
            [
              "Residual risk",
              "medium"
            ],
            [
              "Owner",
              "Chief Medical Officer"
            ],
            [
              "Residual risk accepted by",
              "Hospital Board"
            ],
            [
              "Accepted on",
              "2026-04-01"
            ]
          ]
        }
      ]
    },
    {
      "heading": "AI risk: Nursing acuity and risk scoring",
      "mappedTo": [
        "23894-6.4",
        "23894-6.5",
        "42001-8.3",
        "23894-Annex-A",
        "23894-Annex-B"
      ],
      "blocks": [
        {
          "kind": "fields",
          "rows": [
            [
              "AI system",
              "Nursing acuity and risk scoring"
            ],
            [
              "Human oversight",
              "Human-in-the-loop: a named, competent person reviews each output before it is acted on"
            ],
            [
              "Overseen by",
              "Chief Nursing Officer"
            ],
            [
              "Risk",
              "A patient's acuity is scored too low and the ward plans less care than the patient needs, and the score errs more for some groups, such as older patients, patients with a disability or those who do not speak the local language."
            ],
            [
              "Objectives it bears on",
              "Safety, Fairness"
            ],
            [
              "Where it comes from",
              "Risk sources related to machine learning, Level of automation"
            ],
            [
              "Likelihood",
              "possible"
            ],
            [
              "Consequence",
              "major"
            ],
            [
              "Treatment",
              "Nurses can override any score and every override is logged; scores are compared with outcomes each quarter."
            ],
            [
              "Treated by",
              "Oversee AI Outputs; Keep AI Event Logs; Monitor AI Performance and Incidents"
            ],
            [
              "Residual risk",
              "medium"
            ],
            [
              "Owner",
              "Chief Nursing Officer"
            ],
            [
              "Residual risk accepted by",
              "Hospital Board"
            ],
            [
              "Accepted on",
              "2026-04-01"
            ]
          ]
        }
      ]
    },
    {
      "heading": "AI risk: Nursing-quality analytics",
      "mappedTo": [
        "23894-6.4",
        "23894-6.5",
        "42001-8.3",
        "23894-Annex-A",
        "23894-Annex-B"
      ],
      "blocks": [
        {
          "kind": "fields",
          "rows": [
            [
              "AI system",
              "Nursing-quality analytics"
            ],
            [
              "Human oversight",
              "Human-over-the-loop: review by exception; override always available"
            ],
            [
              "Risk",
              "Gaps in the ward data skew the indicators and point improvement work at the wrong wards."
            ],
            [
              "Objectives it bears on",
              "Robustness, Transparency and explainability"
            ],
            [
              "Where it comes from",
              "Complexity of environment"
            ],
            [
              "Likelihood",
              "possible"
            ],
            [
              "Consequence",
              "minor"
            ],
            [
              "Treatment",
              "Data completeness is checked before each report, and its caveats travel with the figures."
            ],
            [
              "Treated by",
              "No control of the management system carries it out: it rests on the system's own design and its department's practice, as the run-time controls cover the high-risk uses only."
            ],
            [
              "Residual risk",
              "low"
            ],
            [
              "Owner",
              "Chief Nursing Officer"
            ],
            [
              "Residual risk accepted by",
              "Chief Nursing Officer"
            ],
            [
              "Accepted on",
              "2026-03-16"
            ]
          ]
        }
      ]
    },
    {
      "heading": "AI risk: Order-entry decision support",
      "mappedTo": [
        "23894-6.4",
        "23894-6.5",
        "42001-8.3",
        "23894-Annex-A",
        "23894-Annex-B"
      ],
      "blocks": [
        {
          "kind": "fields",
          "rows": [
            [
              "AI system",
              "Order-entry decision support"
            ],
            [
              "Human oversight",
              "Human-in-the-loop: a named, competent person reviews each output before it is acted on"
            ],
            [
              "Overseen by",
              "Attending Physician"
            ],
            [
              "Risk",
              "An alert misses a harmful order, or so many alerts fire that clinicians override them out of habit."
            ],
            [
              "Objectives it bears on",
              "Safety, Robustness"
            ],
            [
              "Where it comes from",
              "Level of automation, Complexity of environment"
            ],
            [
              "Likelihood",
              "possible"
            ],
            [
              "Consequence",
              "major"
            ],
            [
              "Treatment",
              "The alert rules are tuned with pharmacy and the prescribers; override rates are watched and reviewed each quarter."
            ],
            [
              "Treated by",
              "Monitor AI Performance and Incidents"
            ],
            [
              "Residual risk",
              "medium"
            ],
            [
              "Owner",
              "Chief Medical Officer"
            ],
            [
              "Residual risk accepted by",
              "Hospital Board"
            ],
            [
              "Accepted on",
              "2026-04-01"
            ]
          ]
        }
      ]
    },
    {
      "heading": "AI risk: Patient digital assistant",
      "mappedTo": [
        "23894-6.4",
        "23894-6.5",
        "42001-8.3",
        "23894-Annex-A",
        "23894-Annex-B"
      ],
      "blocks": [
        {
          "kind": "fields",
          "rows": [
            [
              "AI system",
              "Patient digital assistant"
            ],
            [
              "Human oversight",
              "Human-on-the-loop: AI disclosed to the person, sampled review, a human route on request"
            ],
            [
              "Risk",
              "Patients do not realise they are talking to software, or it gives advice it should not give."
            ],
            [
              "Objectives it bears on",
              "Transparency and explainability, Safety"
            ],
            [
              "Where it comes from",
              "Level of automation, Complexity of environment"
            ],
            [
              "Likelihood",
              "possible"
            ],
            [
              "Consequence",
              "moderate"
            ],
            [
              "Treatment",
              "It says at the start that it is an AI assistant, declines clinical advice, and hands over to staff on request or on warning words."
            ],
            [
              "Treated by",
              "No control of the management system carries it out: it rests on the system's own design and its department's practice, as the run-time controls cover the high-risk uses only."
            ],
            [
              "Residual risk",
              "low"
            ],
            [
              "Owner",
              "CFO / COO"
            ],
            [
              "Residual risk accepted by",
              "CFO / COO"
            ],
            [
              "Accepted on",
              "2026-03-16"
            ]
          ]
        }
      ]
    },
    {
      "heading": "AI risk: Predictive maintenance",
      "mappedTo": [
        "23894-6.4",
        "23894-6.5",
        "42001-8.3",
        "23894-Annex-A",
        "23894-Annex-B"
      ],
      "blocks": [
        {
          "kind": "fields",
          "rows": [
            [
              "AI system",
              "Predictive maintenance"
            ],
            [
              "Human oversight",
              "Human-over-the-loop: review by exception; override always available"
            ],
            [
              "Risk",
              "A failing building system is not predicted and fails without warning."
            ],
            [
              "Objectives it bears on",
              "Safety, Robustness"
            ],
            [
              "Where it comes from",
              "Complexity of environment, Risk sources related to machine learning"
            ],
            [
              "Likelihood",
              "possible"
            ],
            [
              "Consequence",
              "moderate"
            ],
            [
              "Treatment",
              "Planned maintenance keeps its schedule, and predictions only bring work forward."
            ],
            [
              "Treated by",
              "No control of the management system carries it out: it rests on the system's own design and its department's practice, as the run-time controls cover the high-risk uses only."
            ],
            [
              "Residual risk",
              "low"
            ],
            [
              "Owner",
              "CFO / COO"
            ],
            [
              "Residual risk accepted by",
              "CFO / COO"
            ],
            [
              "Accepted on",
              "2026-03-16"
            ]
          ]
        }
      ]
    },
    {
      "heading": "AI risk: Restricted patient service administration",
      "mappedTo": [
        "23894-6.4",
        "23894-6.5",
        "42001-8.3",
        "23894-Annex-A",
        "23894-Annex-B"
      ],
      "blocks": [
        {
          "kind": "fields",
          "rows": [
            [
              "AI system",
              "Restricted patient service administration"
            ],
            [
              "Human oversight",
              "Human-over-the-loop: review by exception; override always available"
            ],
            [
              "Risk",
              "A restricted patient's details reach staff who should not see them."
            ],
            [
              "Objectives it bears on",
              "Privacy, Security"
            ],
            [
              "Where it comes from",
              "Complexity of environment"
            ],
            [
              "Likelihood",
              "unlikely"
            ],
            [
              "Consequence",
              "major"
            ],
            [
              "Treatment",
              "Access follows the restricted-access rules, and every access is logged and reviewed."
            ],
            [
              "Treated by",
              "No control of the management system carries it out: it rests on the system's own design and its department's practice, as the run-time controls cover the high-risk uses only."
            ],
            [
              "Residual risk",
              "low"
            ],
            [
              "Owner",
              "CFO / COO"
            ],
            [
              "Residual risk accepted by",
              "CFO / COO"
            ],
            [
              "Accepted on",
              "2026-03-16"
            ]
          ]
        }
      ]
    },
    {
      "heading": "AI risk: Results prioritisation",
      "mappedTo": [
        "23894-6.4",
        "23894-6.5",
        "42001-8.3",
        "23894-Annex-A",
        "23894-Annex-B"
      ],
      "blocks": [
        {
          "kind": "fields",
          "rows": [
            [
              "AI system",
              "Results prioritisation"
            ],
            [
              "Human oversight",
              "Human-in-the-loop: a named, competent person reviews each output before it is acted on"
            ],
            [
              "Overseen by",
              "Lab Technologist"
            ],
            [
              "Risk",
              "A critical result is ranked low and reaches the treating clinician late."
            ],
            [
              "Objectives it bears on",
              "Safety"
            ],
            [
              "Where it comes from",
              "Level of automation, Risk sources related to machine learning"
            ],
            [
              "Likelihood",
              "unlikely"
            ],
            [
              "Consequence",
              "severe"
            ],
            [
              "Treatment",
              "Critical values still trigger the standard phone call and the ranking only orders the rest; any miss is handled as an incident."
            ],
            [
              "Treated by",
              "Monitor AI Performance and Incidents"
            ],
            [
              "Residual risk",
              "low"
            ],
            [
              "Owner",
              "Chief Medical Officer"
            ],
            [
              "Residual risk accepted by",
              "Chief Medical Officer"
            ],
            [
              "Accepted on",
              "2026-03-16"
            ]
          ]
        }
      ]
    },
    {
      "heading": "AI risk: Staff performance monitoring",
      "mappedTo": [
        "23894-6.4",
        "23894-6.5",
        "42001-8.3",
        "23894-Annex-A",
        "23894-Annex-B"
      ],
      "blocks": [
        {
          "kind": "fields",
          "rows": [
            [
              "AI system",
              "Staff performance monitoring"
            ],
            [
              "Human oversight",
              "Human-in-the-loop: a named, competent person reviews each output before it is acted on"
            ],
            [
              "Overseen by",
              "Chief Nursing Officer"
            ],
            [
              "Risk",
              "Monitoring misjudges a worker's performance or intrudes on their privacy."
            ],
            [
              "Objectives it bears on",
              "Fairness, Privacy, Accountability"
            ],
            [
              "Where it comes from",
              "Level of automation, Lack of transparency and explainability"
            ],
            [
              "Likelihood",
              "possible"
            ],
            [
              "Consequence",
              "major"
            ],
            [
              "Treatment",
              "No decision about a worker rests on the system alone; staff are told what is monitored, and staff representatives review the use twice a year."
            ],
            [
              "Treated by",
              "Oversee AI Outputs; Inform and Explain AI Use"
            ],
            [
              "Residual risk",
              "medium"
            ],
            [
              "Owner",
              "Chief Nursing Officer"
            ],
            [
              "Residual risk accepted by",
              "Hospital Board"
            ],
            [
              "Accepted on",
              "2026-04-01"
            ]
          ]
        }
      ]
    },
    {
      "heading": "AI risk: Staff scheduling and task allocation",
      "mappedTo": [
        "23894-6.4",
        "23894-6.5",
        "42001-8.3",
        "23894-Annex-A",
        "23894-Annex-B"
      ],
      "blocks": [
        {
          "kind": "fields",
          "rows": [
            [
              "AI system",
              "Staff scheduling and task allocation"
            ],
            [
              "Human oversight",
              "Human-in-the-loop: a named, competent person reviews each output before it is acted on"
            ],
            [
              "Overseen by",
              "Chief Nursing Officer"
            ],
            [
              "Risk",
              "Allocations treat some staff unfairly, or lean on personal traits rather than availability and skills."
            ],
            [
              "Objectives it bears on",
              "Fairness, Privacy, Transparency and explainability"
            ],
            [
              "Where it comes from",
              "Level of automation, Lack of transparency and explainability"
            ],
            [
              "Likelihood",
              "possible"
            ],
            [
              "Consequence",
              "major"
            ],
            [
              "Treatment",
              "The rules use availability and skills only; outcomes are checked for unfair patterns each quarter, and staff can ask for a person to review an allocation."
            ],
            [
              "Treated by",
              "Check AI Input Data; Oversee AI Outputs; Monitor AI Performance and Incidents"
            ],
            [
              "Residual risk",
              "medium"
            ],
            [
              "Owner",
              "Chief Nursing Officer"
            ],
            [
              "Residual risk accepted by",
              "Hospital Board"
            ],
            [
              "Accepted on",
              "2026-04-01"
            ]
          ]
        }
      ]
    },
    {
      "heading": "AI risk: Surgical decision support",
      "mappedTo": [
        "23894-6.4",
        "23894-6.5",
        "42001-8.3",
        "23894-Annex-A",
        "23894-Annex-B"
      ],
      "blocks": [
        {
          "kind": "fields",
          "rows": [
            [
              "AI system",
              "Surgical decision support"
            ],
            [
              "Human oversight",
              "Human-in-the-loop: a named, competent person reviews each output before it is acted on"
            ],
            [
              "Overseen by",
              "Surgeon"
            ],
            [
              "Risk",
              "A planning suggestion does not fit the patient's anatomy and misleads the surgical team."
            ],
            [
              "Objectives it bears on",
              "Safety, Robustness"
            ],
            [
              "Where it comes from",
              "Technology readiness, Risk sources related to machine learning"
            ],
            [
              "Likelihood",
              "unlikely"
            ],
            [
              "Consequence",
              "severe"
            ],
            [
              "Treatment",
              "The operating surgeon confirms every plan, and suggestions are checked against the imaging at each case review."
            ],
            [
              "Treated by",
              "Oversee AI Outputs; Monitor AI Performance and Incidents"
            ],
            [
              "Residual risk",
              "medium"
            ],
            [
              "Owner",
              "Chief Medical Officer"
            ],
            [
              "Residual risk accepted by",
              "Hospital Board"
            ],
            [
              "Accepted on",
              "2026-04-01"
            ]
          ]
        }
      ]
    },
    {
      "heading": "Monitoring and review",
      "mappedTo": [
        "23894-6.6"
      ],
      "blocks": [
        {
          "kind": "paragraph",
          "text": "The model holds no review field of its own: where a treatment sets a review, its text says so."
        }
      ]
    }
  ]
}