Illustrative, not pack output

AI governance portfolio

An AI management system for the fictional hospital, generated from the same model as the report and the explorer: its scope and AI policy, roles, a risk assessment, two AI system impact assessments, an internal audit and a management review, a map of ISO/IEC 42001 clause coverage, and a crosswalk from EU obligations to the controls. Every document is synthetic.

This reference model is designed to support conformity with ISO/IEC 42001:2023. Nothing here is legal advice, a certification or a conformity finding.

Illustrative, not pack output

A 15-minute walk-through

A script for a customer conversation, in this order. Each step opens one document below.

  1. Scope and policy2 minutesWhich AI systems the management system covers, what it leaves out, and what the policy commits the hospital to.
  2. Roles2 minutesWho owns each AI system, who approves its use, and who answers for it.
  3. Risk3 minutesPick one AI system: its risks, the treatment chosen for each, and the risk left after it.
  4. Impact3 minutesThe two impact assessments, emergency triage and deterioration warning: who each system affects, the harms and benefits weighed, and the misuse foreseen.
  5. Audit and review2 minutesWhat each internal audit found and what was done about it; then what the management review decided.
  6. Coverage2 minutesWhich ISO/IEC 42001 clauses the model covers, covers in part (each gap is named) or does not cover.
  7. Traceability1 minuteEach EU obligation, the control that realizes it, and the ISO/IEC 42001 subclauses that control serves.

Obligation coverage, as the model computes it

An instance counts when a control in the model is linked to a synthetic record for that system. The figure does not check a record's content, a control's operation or a date of application, and it is not a conformity assessment, an audit or a legal finding.

Instances within scope under the model's rulings

With evidence
143 of 144
On an AI system
142 of 144
On the organisation
2 of 144

Rows of the crosswalk

Which rows apply is proposed, pending self-review.

Apply to a subject
17 of 27
Apply to an AI system
15 of 27
Apply to the organisation only
2 of 27
Apply to none yet
10 of 27
Lack an article or a date
4 of 27

Without evidence: AI Literacy of Staff (AIA Art 4)

Instances by the model's own effective dates

In application on the release date
63 of 144
Apply from a later date
81 of 144

Where a row names two dates, its operative rule decides.

These figures as JSONsha256: 9b4b0397e46c62fa13bee013cf2105423b1b0d016c32dbd1f1c083426f949936

Clauses the model covers in part

From the clause-coverage map: each clause the model covers only in part, with the gap the map names.

  • 6.1.3 AI risk treatmentEach risk record is set to name the treatment chosen, the risk left after it and the executive who owns it. Gap: No statement of applicability is modelled. It would list the Annex A controls, and the public preview this pack was built from lists only A.1 of Annex A, so none is named here.
  • 7.5.3 Control of documented informationA control process is set to keep the AI systems' event logs, which a service retains for their planned period. Gap: How the other records are stored, shared and versioned is not modelled.
  • 8.2 AI risk assessmentA risk record is set up for each AI system, with its likelihood, consequence and residual risk on fixed scales. Gap: No record holds a date for the next assessment, so when the risks are assessed again is not modelled.
  • 8.4 AI system impact assessmentTwo AI system impact assessments are set to weigh harms, benefits and misuse for the people an AI system affects, data protection and fundamental rights impact assessments are recorded for the systems that have one, and the approval process is set to assess each use before it goes live. Gap: The internal audit of that process found one of five sampled uses live two weeks before its impact assessment was signed; the go-live checklist now stops on an unsigned one.
  • 9.2 Internal auditAn internal-audit record is set up for each control: its auditor, scope, sample, criteria, finding, detail, corrective action, the date that action is due, and status. Gap: No programme of audits is modelled: the records hold one round on one date and two follow-ups, not which audits run, when or how often.

Synthetic: an illustrative record, generated from the model of a fictional hospital in a synthetic reference architecture. It holds no customer data and no record of an actual hospital.

AI management system: demonstration pack

What the pack holds and how it was made.

What this is

The records an AI management system keeps, generated from one architecture model of a fictional hospital. Each document below is drawn from that model, from a catalogue of the standards' clause numbers and titles, and from a clause map written for this model. Where a document has nothing in the model to draw on, it says so.

Documents

DocumentWhat it records
AI management system: scope and AI policyWhere the management system applies, what it leaves out, the AI policy and the AI objectives.
AI management system: roles and accountabilityWho approves, who carries out each control, who oversees each high-risk AI system and who owns each record.
AI risk assessmentA risk record for each of the 17 AI systems in scope, on fixed scales, with its treatment, the risk left after it and who accepted that risk.
AI system impact assessment: Deterioration warningThe impact assessment of the deterioration warning AI system: who it affects, its harms and benefits, and what is done about them.
AI system impact assessment: Emergency triageThe impact assessment of the emergency triage AI system: who it affects, its harms and benefits, and what is done about them.
AI management system: internal auditAn internal audit of each of the 8 controls, and 2 follow-up audits: what was checked, what was found and what was done.
AI management system: management reviewTop management's review of the management system: its inputs, conclusions and actions.
ISO/IEC 42001:2023 clause-coverage mapWhere the model holds each subclause of ISO/IEC 42001:2023 clauses 4 to 10, at both levels the table of contents lists, and why where it does not.
EU obligations and ISO/IEC 42001:2023: crosswalk through the controlsFor each EU obligation the model records, the control that realizes it and the ISO/IEC 42001:2023 subclauses whose clause-map entry names that control.

This reference model is designed to support conformity with ISO/IEC 42001:2023.

Not legal advice: obligation names are short forms, and the act's text governs. No certification or conformity finding; not affiliated with or endorsed by ISO or IEC. Standard numbers and titles are cited from ISO's public preview.

Document 00-coverThis document as JSONsha256: 6c2c932eb9bb489fa5675e6f4ff49fe707bc1b009576e5f93c3cfd542994d38b

Synthetic: an illustrative record, generated from the model of a fictional hospital in a synthetic reference architecture. It holds no customer data and no record of an actual hospital.

AI management system: scope and AI policy

Where the management system applies, what it leaves out, the AI policy and the AI objectives.

Scope

Mapped to 42001-4.3

Every AI system the hospital uses in care, operations and administration, from the decision to use it until it is retired, and the processes that govern them.

What the scope leaves out

Mapped to 42001-4.3

Left outWhy
AI tools staff use on their own devices outside hospital systemsthe hospital neither deploys nor controls them, and the acceptable-use rules cover them instead
AI used only in approved research studiesa separate research-governance route approves and watches it, and it reaches no patient's care
general-purpose features inside office softwarethey hold no patient or staff record and make no decision about a person

AI systems in scope (17)

Mapped to 42001-4.3

AI systemPurposeAI Act risk classGround
Clinical note draftingDrafting care notes for clinician reviewnot-high-riskNo medical purpose for an individual patient and no Annex III point; a change of purpose re-classifies it
Coding, billing and claimsCoding, billing and claimsnot-high-riskCoding and billing only
Deterioration warningCare-pathway and deterioration warningshigh-riskArt 6(1) and Annex I, as its provider declares it a medical device of class IIa or higher
Diagnostic supportDiagnostic supporthigh-riskArt 6(1) and Annex I, as its provider declares it a medical device of class IIa or higher
Emergency triageEmergency patient triagehigh-riskAnnex III point 5(d), and possibly also Art 6(1) and Annex I if scoring each patient's urgency makes it device software (MDR Art 2(1), Annex VIII Rule 11), a device question the Clinical AI Safety Lead settles with its provider by 2027-06-30
Image analysisImage analysishigh-riskArt 6(1) and Annex I, as its provider declares it a medical device of class IIa or higher
Medication checkingMedication checkshigh-riskArt 6(1) and Annex I, as its provider declares it a medical device of class IIa or higher
Nursing acuity and risk scoringNursing acuity and risk scoringhigh-riskArt 6(1) and Annex I, as its provider declares it a medical device of class IIa or higher
Nursing-quality analyticsAggregate nursing-quality analyticsnot-high-riskNo medical purpose for an individual patient and no Annex III point; a change of purpose re-classifies it
Order-entry decision supportDecision support at order entryhigh-riskArt 6(1) and Annex I, as its provider declares it a medical device of class IIa or higher
Patient digital assistantA digital assistant that talks with patientstransparencyArt 50(1) transparency, which binds the provider, a reading the AI Governance Approver confirms by 2026-07-31; high-risk only if it triages emergency patients (Annex III point 5(d))
Predictive maintenancePredictive maintenance and building operationsnot-high-riskAnnex III point 2 covers safety components in critical digital infrastructure, road traffic and the supply of water, gas, heating or electricity; a hospital's own building systems read as outside it, a reading the AI Governance Approver confirms by 2027-06-30
Restricted patient service administrationAdministering a restricted-access patient servicenot-high-riskNo Annex III point; its confidentiality is a data-protection matter
Results prioritisationPrioritising critical resultshigh-riskArt 6(1) and Annex I, as its provider declares it a medical device of class IIa or higher
Staff performance monitoringMonitoring and evaluating staff performancehigh-riskArt 6(2) and Annex III point 4(b)
Staff scheduling and task allocationStaff scheduling and task allocationhigh-riskArt 6(2) and Annex III point 4(b)
Surgical decision supportSurgical decision supporthigh-riskArt 6(1) and Annex I, as its provider declares it a medical device of class IIa or higher

The hospital's role under the AI Act, with the condition under which it changes:

Every AI system in scope
Deployer (AIA Art 3(4)). It becomes the provider of a high-risk system under Art 25(1) if it puts its own name or mark on the system, substantially modifies it, or changes its intended purpose so that it becomes high-risk.

AI policy

Mapped to 42001-5.2

Approved by
Hospital Board
Approved on
2026-03-02
PrincipleStatementCarried out by
AI policy: Assess before useNo AI system goes into use until its purpose, its risks and its effects on people have been assessed and the use approved.Assess and Approve AI Uses
AI policy: Be open with peoplePatients and staff are told when AI plays a part in a decision about them, and can have that part explained.Inform and Explain AI Use
AI policy: Equip the people who use AIStaff who operate or rely on an AI system learn what it can and cannot do before they use it.Train Staff in AI Literacy
AI policy: Watch while in useEvery AI system in use is watched for performance, drift and incidents, and problems reach the people who can act on them.Monitor AI Performance and Incidents

AI objectives

Mapped to 42001-6.2

ObjectiveMeasureTarget
AI objective: Every high-risk AI system assessedthe share of high-risk AI systems with a current risk record and, where one is required, an impact assessmentall of them before first use, and again at least once a year
AI objective: Incidents handled on timethe share of AI incidents triaged within two working days of being reported, and the share of the reports to the provider and the authorities made on timeat least 95 percent triaged each quarter, and every report on time: a serious incident immediately to the provider, then to the importer or distributor and the market surveillance authority, or to that authority within the time limits of AI Act Art 73 if the provider cannot be reached (AI Act Art 26(5)); on a risk that a high-risk AI system presents, the provider or distributor and the market surveillance authority without undue delay, and the system's use suspended (Art 26(5)); and a personal-data breach to the data protection supervisory authority without undue delay, within 72 hours where feasible (GDPR Art 33(1)). For a system that is a device under the medical device regulations, or a device's safety component, the AI Act limits the serious incidents to notify to infringements of the obligations that protect fundamental rights, and they go to the national competent authority that the Member State where the incident occurred chose for that purpose (AI Act Art 73(10))
AI objective: Staff trained before usethe share of staff using an AI system who finished their AI-literacy training before first useat least 90 percent, rising to all within a year

This reference model is designed to support conformity with ISO/IEC 42001:2023.

Not legal advice: obligation names are short forms, and the act's text governs. No certification or conformity finding; not affiliated with or endorsed by ISO or IEC. Standard numbers and titles are cited from ISO's public preview.

Document 01-scope-and-policyThis document as JSONsha256: 72eb286f12e461e9e692e3da482c5b07aca22d1d06404282d49a692618d29f14

Synthetic: an illustrative record, generated from the model of a fictional hospital in a synthetic reference architecture. It holds no customer data and no record of an actual hospital.

AI management system: roles and accountability

Who approves, who carries out each control, who oversees each high-risk AI system and who owns each record.

Approval authority

Mapped to 42001-5.1, 42001-5.3

BodyRole it fills
AI Governance CommitteeAI Governance Approver
The AI policy
approved by Hospital Board on 2026-03-02

Controls and who carries them out

Mapped to 42001-5.3, 42001-8.1

ControlCarried out by
Assess AI ImpactData Protection Officer; Fundamental Rights Assessment Lead
Assess and Approve AI UsesAI Governance Approver; AI System Owner; Clinical AI Safety Lead
Check AI Input DataHealth Information Manager
Inform and Explain AI UseAI System Owner
Keep AI Event LogsHealth Information Manager
Monitor AI Performance and IncidentsAI System Owner; Clinical AI Safety Lead
Oversee AI OutputsAttending Physician; Chief Nursing Officer; Lab Technologist; Pharmacist; Radiologist; Registered Nurse; Surgeon
Train Staff in AI LiteracyAI System Owner

Who oversees each high-risk AI system

Mapped to 42001-5.3

Each system's outputs are reviewed by the people who act on them: the role that performs the process its service supports.

AI systemOverseen by
Deterioration warningAttending Physician
Diagnostic supportRadiologist
Emergency triageRegistered Nurse
Image analysisRadiologist
Medication checkingPharmacist
Nursing acuity and risk scoringChief Nursing Officer
Order-entry decision supportAttending Physician
Results prioritisationLab Technologist
Staff performance monitoringChief Nursing Officer
Staff scheduling and task allocationChief Nursing Officer
Surgical decision supportSurgeon

Who owns the records

Mapped to 42001-5.3

OwnerKindRecords it owns
CFO / COOexecutive3 risk records
CISO / Compliance Officerexecutive1 risk record
Chief Medical Officerexecutive8 risk records
Chief Nursing Officerexecutive5 risk records
Clinical AI Safety Leadrole2 impact assessments
Hospital Boardbody1 management review

Data-protection roles

Mapped to 42001-5.3

Not modelled: the data-protection roles, among them the controller, its processors and the data protection officer (GDPR Art 37), sit outside the AI roles this model holds.

AI Governance Approver

Mapped to 42001-5.3

Carries out
1 control
Owns
no record

The controls it carries out:

  • Assess and Approve AI Uses

AI System Owner

Mapped to 42001-5.3

Carries out
4 controls
Owns
no record

The controls it carries out:

  • Assess and Approve AI Uses
  • Inform and Explain AI Use
  • Monitor AI Performance and Incidents
  • Train Staff in AI Literacy

Attending Physician

Mapped to 42001-5.3

Carries out
1 control
Owns
no record
Oversees
2 AI systems

The controls it carries out:

  • Oversee AI Outputs

The AI systems it oversees:

  • Deterioration warning
  • Order-entry decision support

Chief Nursing Officer

Mapped to 42001-5.3

Carries out
1 control
Owns
no record
Oversees
3 AI systems

The controls it carries out:

  • Oversee AI Outputs

The AI systems it oversees:

  • Nursing acuity and risk scoring
  • Staff performance monitoring
  • Staff scheduling and task allocation

Clinical AI Safety Lead

Mapped to 42001-5.3

Carries out
2 controls
Owns
2 records

The controls it carries out:

  • Assess and Approve AI Uses
  • Monitor AI Performance and Incidents

The records it owns:

  • AI impact assessment: Deterioration warning
  • AI impact assessment: Emergency triage

Data Protection Officer

Mapped to 42001-5.3

Carries out
1 control
Owns
no record

The controls it carries out:

  • Assess AI Impact

Fundamental Rights Assessment Lead

Mapped to 42001-5.3

Carries out
1 control
Owns
no record

The controls it carries out:

  • Assess AI Impact

Health Information Manager

Mapped to 42001-5.3

Carries out
2 controls
Owns
no record

The controls it carries out:

  • Check AI Input Data
  • Keep AI Event Logs

Lab Technologist

Mapped to 42001-5.3

Carries out
1 control
Owns
no record
Oversees
1 AI system

The controls it carries out:

  • Oversee AI Outputs

The AI systems it oversees:

  • Results prioritisation

Pharmacist

Mapped to 42001-5.3

Carries out
1 control
Owns
no record
Oversees
1 AI system

The controls it carries out:

  • Oversee AI Outputs

The AI systems it oversees:

  • Medication checking

Radiologist

Mapped to 42001-5.3

Carries out
1 control
Owns
no record
Oversees
2 AI systems

The controls it carries out:

  • Oversee AI Outputs

The AI systems it oversees:

  • Diagnostic support
  • Image analysis

Registered Nurse

Mapped to 42001-5.3

Carries out
1 control
Owns
no record
Oversees
1 AI system

The controls it carries out:

  • Oversee AI Outputs

The AI systems it oversees:

  • Emergency triage

Surgeon

Mapped to 42001-5.3

Carries out
1 control
Owns
no record
Oversees
1 AI system

The controls it carries out:

  • Oversee AI Outputs

The AI systems it oversees:

  • Surgical decision support

This reference model is designed to support conformity with ISO/IEC 42001:2023.

Not legal advice: obligation names are short forms, and the act's text governs. No certification or conformity finding; not affiliated with or endorsed by ISO or IEC. Standard numbers and titles are cited from ISO's public preview.

Document 02-roles-and-accountabilityThis document as JSONsha256: b81ef9ac8a3e4341fcf35eba26067a75f169a0dee0ccb6d0b2e35a1d6b4f8bcc

Synthetic: an illustrative record, generated from the model of a fictional hospital in a synthetic reference architecture. It holds no customer data and no record of an actual hospital.

AI risk assessment

A risk record for each of the 17 AI systems in scope, on fixed scales, with its treatment, the risk left after it and who accepted that risk.

Risk criteria

Mapped to 23894-6.3, 23894-Annex-A, 23894-Annex-B

Likelihood, lowest to highest
rare, unlikely, possible, likely, almost certain
Consequence, lowest to highest
negligible, minor, moderate, major, severe
Residual risk, lowest to highest
low, medium, high
Objectives a risk can bear on
Accountability, AI expertise, Availability and quality of training and test data, Environmental impact, Fairness, Maintainability, Privacy, Robustness, Safety, Security, Transparency and explainability
Sources a risk can come from
Complexity of environment, Lack of transparency and explainability, Level of automation, Risk sources related to machine learning, System hardware issues, System life cycle issues, Technology readiness
Assessed on
2026-03-16

Risk register

Mapped to 23894-6.4, 42001-8.2

AI systemLikelihoodConsequenceResidual riskOwnerAccepted by
Clinical note draftingpossiblemoderatelowChief Medical OfficerChief Medical Officer
Coding, billing and claimslikelyminorlowCISO / Compliance OfficerCISO / Compliance Officer
Deterioration warningpossibleseveremediumChief Medical OfficerHospital Board
Diagnostic supportpossiblemajormediumChief Medical OfficerHospital Board
Emergency triagepossibleseveremediumChief Nursing OfficerHospital Board
Image analysispossiblemajormediumChief Medical OfficerHospital Board
Medication checkingunlikelyseveremediumChief Medical OfficerHospital Board
Nursing acuity and risk scoringpossiblemajormediumChief Nursing OfficerHospital Board
Nursing-quality analyticspossibleminorlowChief Nursing OfficerChief Nursing Officer
Order-entry decision supportpossiblemajormediumChief Medical OfficerHospital Board
Patient digital assistantpossiblemoderatelowCFO / COOCFO / COO
Predictive maintenancepossiblemoderatelowCFO / COOCFO / COO
Restricted patient service administrationunlikelymajorlowCFO / COOCFO / COO
Results prioritisationunlikelyseverelowChief Medical OfficerChief Medical Officer
Staff performance monitoringpossiblemajormediumChief Nursing OfficerHospital Board
Staff scheduling and task allocationpossiblemajormediumChief Nursing OfficerHospital Board
Surgical decision supportunlikelyseveremediumChief Medical OfficerHospital Board

AI risk: Clinical note drafting

Mapped to 23894-6.4, 23894-6.5, 42001-8.3, 23894-Annex-A, 23894-Annex-B

AI system
Clinical note drafting
Human oversight
Human-over-the-loop: review by exception; override always available
Risk
A drafted note records something the clinician did not say, or leaves out a finding, and is signed unread.
Objectives it bears on
Safety, Accountability
Where it comes from
Level of automation, Risk sources related to machine learning
Likelihood
possible
Consequence
moderate
Treatment
Drafts stay marked as drafts until a clinician edits and signs them; a sample of signed notes is checked each month.
Treated by
No control of the management system carries it out: it rests on the system's own design and its department's practice, as the run-time controls cover the high-risk uses only.
Residual risk
low
Owner
Chief Medical Officer
Residual risk accepted by
Chief Medical Officer
Accepted on
2026-03-16

AI risk: Coding, billing and claims

Mapped to 23894-6.4, 23894-6.5, 42001-8.3, 23894-Annex-A, 23894-Annex-B

AI system
Coding, billing and claims
Human oversight
Human-over-the-loop: review by exception; override always available
Risk
A coding suggestion is wrong and a claim is billed too high or too low.
Objectives it bears on
Accountability
Where it comes from
Risk sources related to machine learning
Likelihood
likely
Consequence
minor
Treatment
A coder confirms every suggestion before a claim leaves the hospital, more than the review by exception its tier sets as the floor, and a monthly audit samples coded episodes.
Treated by
No control of the management system carries it out: it rests on the system's own design and its department's practice, as the run-time controls cover the high-risk uses only.
Residual risk
low
Owner
CISO / Compliance Officer
Residual risk accepted by
CISO / Compliance Officer
Accepted on
2026-03-16

AI risk: Deterioration warning

Mapped to 23894-6.4, 23894-6.5, 42001-8.3, 23894-Annex-A, 23894-Annex-B

AI system
Deterioration warning
Human oversight
Human-in-the-loop: a named, competent person reviews each output before it is acted on
Overseen by
Attending Physician
Risk
A patient who is getting worse is not flagged in time, or false alarms teach the ward to ignore the warnings.
Objectives it bears on
Safety, Robustness, Availability and quality of training and test data
Where it comes from
Risk sources related to machine learning, Complexity of environment
Likelihood
possible
Consequence
severe
Treatment
Warnings add to routine observations and never replace them; alarm rates and missed events are reviewed every month.
Treated by
Oversee AI Outputs; Monitor AI Performance and Incidents
Residual risk
medium
Owner
Chief Medical Officer
Residual risk accepted by
Hospital Board
Accepted on
2026-04-01

AI risk: Diagnostic support

Mapped to 23894-6.4, 23894-6.5, 42001-8.3, 23894-Annex-A, 23894-Annex-B

AI system
Diagnostic support
Human oversight
Human-in-the-loop: a named, competent person reviews each output before it is acted on
Overseen by
Radiologist
Risk
A suggested diagnosis anchors the clinician on the wrong condition.
Objectives it bears on
Safety, Transparency and explainability
Where it comes from
Lack of transparency and explainability, Risk sources related to machine learning
Likelihood
possible
Consequence
major
Treatment
Each suggestion shows its evidence and its uncertainty, clinicians record their own reasoning, and cases are sampled each quarter.
Treated by
Oversee AI Outputs; Monitor AI Performance and Incidents
Residual risk
medium
Owner
Chief Medical Officer
Residual risk accepted by
Hospital Board
Accepted on
2026-04-01

AI risk: Emergency triage

Mapped to 23894-6.4, 23894-6.5, 42001-8.3, 23894-Annex-A, 23894-Annex-B

AI system
Emergency triage
Human oversight
Human-in-the-loop: a named, competent person reviews each output before it is acted on
Overseen by
Registered Nurse
Risk
A patient's urgency is rated too low and their care is delayed, more often for older patients and for those who do not speak the local language, whom the supplier's training data holds fewer of.
Objectives it bears on
Safety, Fairness, Availability and quality of training and test data
Where it comes from
Risk sources related to machine learning, Level of automation
Likelihood
possible
Consequence
severe
Treatment
Triage staff confirm or change every score; under-triage is reviewed weekly for the first three months, then monthly.
Treated by
Oversee AI Outputs; Monitor AI Performance and Incidents
Residual risk
medium
Owner
Chief Nursing Officer
Residual risk accepted by
Hospital Board
Accepted on
2026-04-01

AI risk: Image analysis

Mapped to 23894-6.4, 23894-6.5, 42001-8.3, 23894-Annex-A, 23894-Annex-B

AI system
Image analysis
Human oversight
Human-in-the-loop: a named, competent person reviews each output before it is acted on
Overseen by
Radiologist
Risk
A missed or false finding on an image delays or misdirects a diagnosis.
Objectives it bears on
Safety, Robustness
Where it comes from
Risk sources related to machine learning, Lack of transparency and explainability
Likelihood
possible
Consequence
major
Treatment
A specialist still reads every image and the system only flags; disagreement between the two is tracked.
Treated by
Oversee AI Outputs; Monitor AI Performance and Incidents
Residual risk
medium
Owner
Chief Medical Officer
Residual risk accepted by
Hospital Board
Accepted on
2026-04-01

AI risk: Medication checking

Mapped to 23894-6.4, 23894-6.5, 42001-8.3, 23894-Annex-A, 23894-Annex-B

AI system
Medication checking
Human oversight
Human-in-the-loop: a named, competent person reviews each output before it is acted on
Overseen by
Pharmacist
Risk
A dangerous interaction or dose is not flagged.
Objectives it bears on
Safety
Where it comes from
System life cycle issues
Likelihood
unlikely
Consequence
severe
Treatment
A pharmacy check still follows every order, and the supplier updates the rule set with each change to the hospital's medicines list, which the hospital sends it.
Treated by
Oversee AI Outputs; Check AI Input Data
Residual risk
medium
Owner
Chief Medical Officer
Residual risk accepted by
Hospital Board
Accepted on
2026-04-01

AI risk: Nursing acuity and risk scoring

Mapped to 23894-6.4, 23894-6.5, 42001-8.3, 23894-Annex-A, 23894-Annex-B

AI system
Nursing acuity and risk scoring
Human oversight
Human-in-the-loop: a named, competent person reviews each output before it is acted on
Overseen by
Chief Nursing Officer
Risk
A patient's acuity is scored too low and the ward plans less care than the patient needs, and the score errs more for some groups, such as older patients, patients with a disability or those who do not speak the local language.
Objectives it bears on
Safety, Fairness
Where it comes from
Risk sources related to machine learning, Level of automation
Likelihood
possible
Consequence
major
Treatment
Nurses can override any score and every override is logged; scores are compared with outcomes each quarter.
Treated by
Oversee AI Outputs; Keep AI Event Logs; Monitor AI Performance and Incidents
Residual risk
medium
Owner
Chief Nursing Officer
Residual risk accepted by
Hospital Board
Accepted on
2026-04-01

AI risk: Nursing-quality analytics

Mapped to 23894-6.4, 23894-6.5, 42001-8.3, 23894-Annex-A, 23894-Annex-B

AI system
Nursing-quality analytics
Human oversight
Human-over-the-loop: review by exception; override always available
Risk
Gaps in the ward data skew the indicators and point improvement work at the wrong wards.
Objectives it bears on
Robustness, Transparency and explainability
Where it comes from
Complexity of environment
Likelihood
possible
Consequence
minor
Treatment
Data completeness is checked before each report, and its caveats travel with the figures.
Treated by
No control of the management system carries it out: it rests on the system's own design and its department's practice, as the run-time controls cover the high-risk uses only.
Residual risk
low
Owner
Chief Nursing Officer
Residual risk accepted by
Chief Nursing Officer
Accepted on
2026-03-16

AI risk: Order-entry decision support

Mapped to 23894-6.4, 23894-6.5, 42001-8.3, 23894-Annex-A, 23894-Annex-B

AI system
Order-entry decision support
Human oversight
Human-in-the-loop: a named, competent person reviews each output before it is acted on
Overseen by
Attending Physician
Risk
An alert misses a harmful order, or so many alerts fire that clinicians override them out of habit.
Objectives it bears on
Safety, Robustness
Where it comes from
Level of automation, Complexity of environment
Likelihood
possible
Consequence
major
Treatment
The alert rules are tuned with pharmacy and the prescribers; override rates are watched and reviewed each quarter.
Treated by
Monitor AI Performance and Incidents
Residual risk
medium
Owner
Chief Medical Officer
Residual risk accepted by
Hospital Board
Accepted on
2026-04-01

AI risk: Patient digital assistant

Mapped to 23894-6.4, 23894-6.5, 42001-8.3, 23894-Annex-A, 23894-Annex-B

AI system
Patient digital assistant
Human oversight
Human-on-the-loop: AI disclosed to the person, sampled review, a human route on request
Risk
Patients do not realise they are talking to software, or it gives advice it should not give.
Objectives it bears on
Transparency and explainability, Safety
Where it comes from
Level of automation, Complexity of environment
Likelihood
possible
Consequence
moderate
Treatment
It says at the start that it is an AI assistant, declines clinical advice, and hands over to staff on request or on warning words.
Treated by
No control of the management system carries it out: it rests on the system's own design and its department's practice, as the run-time controls cover the high-risk uses only.
Residual risk
low
Owner
CFO / COO
Residual risk accepted by
CFO / COO
Accepted on
2026-03-16

AI risk: Predictive maintenance

Mapped to 23894-6.4, 23894-6.5, 42001-8.3, 23894-Annex-A, 23894-Annex-B

AI system
Predictive maintenance
Human oversight
Human-over-the-loop: review by exception; override always available
Risk
A failing building system is not predicted and fails without warning.
Objectives it bears on
Safety, Robustness
Where it comes from
Complexity of environment, Risk sources related to machine learning
Likelihood
possible
Consequence
moderate
Treatment
Planned maintenance keeps its schedule, and predictions only bring work forward.
Treated by
No control of the management system carries it out: it rests on the system's own design and its department's practice, as the run-time controls cover the high-risk uses only.
Residual risk
low
Owner
CFO / COO
Residual risk accepted by
CFO / COO
Accepted on
2026-03-16

AI risk: Restricted patient service administration

Mapped to 23894-6.4, 23894-6.5, 42001-8.3, 23894-Annex-A, 23894-Annex-B

AI system
Restricted patient service administration
Human oversight
Human-over-the-loop: review by exception; override always available
Risk
A restricted patient's details reach staff who should not see them.
Objectives it bears on
Privacy, Security
Where it comes from
Complexity of environment
Likelihood
unlikely
Consequence
major
Treatment
Access follows the restricted-access rules, and every access is logged and reviewed.
Treated by
No control of the management system carries it out: it rests on the system's own design and its department's practice, as the run-time controls cover the high-risk uses only.
Residual risk
low
Owner
CFO / COO
Residual risk accepted by
CFO / COO
Accepted on
2026-03-16

AI risk: Results prioritisation

Mapped to 23894-6.4, 23894-6.5, 42001-8.3, 23894-Annex-A, 23894-Annex-B

AI system
Results prioritisation
Human oversight
Human-in-the-loop: a named, competent person reviews each output before it is acted on
Overseen by
Lab Technologist
Risk
A critical result is ranked low and reaches the treating clinician late.
Objectives it bears on
Safety
Where it comes from
Level of automation, Risk sources related to machine learning
Likelihood
unlikely
Consequence
severe
Treatment
Critical values still trigger the standard phone call and the ranking only orders the rest; any miss is handled as an incident.
Treated by
Monitor AI Performance and Incidents
Residual risk
low
Owner
Chief Medical Officer
Residual risk accepted by
Chief Medical Officer
Accepted on
2026-03-16

AI risk: Staff performance monitoring

Mapped to 23894-6.4, 23894-6.5, 42001-8.3, 23894-Annex-A, 23894-Annex-B

AI system
Staff performance monitoring
Human oversight
Human-in-the-loop: a named, competent person reviews each output before it is acted on
Overseen by
Chief Nursing Officer
Risk
Monitoring misjudges a worker's performance or intrudes on their privacy.
Objectives it bears on
Fairness, Privacy, Accountability
Where it comes from
Level of automation, Lack of transparency and explainability
Likelihood
possible
Consequence
major
Treatment
No decision about a worker rests on the system alone; staff are told what is monitored, and staff representatives review the use twice a year.
Treated by
Oversee AI Outputs; Inform and Explain AI Use
Residual risk
medium
Owner
Chief Nursing Officer
Residual risk accepted by
Hospital Board
Accepted on
2026-04-01

AI risk: Staff scheduling and task allocation

Mapped to 23894-6.4, 23894-6.5, 42001-8.3, 23894-Annex-A, 23894-Annex-B

AI system
Staff scheduling and task allocation
Human oversight
Human-in-the-loop: a named, competent person reviews each output before it is acted on
Overseen by
Chief Nursing Officer
Risk
Allocations treat some staff unfairly, or lean on personal traits rather than availability and skills.
Objectives it bears on
Fairness, Privacy, Transparency and explainability
Where it comes from
Level of automation, Lack of transparency and explainability
Likelihood
possible
Consequence
major
Treatment
The rules use availability and skills only; outcomes are checked for unfair patterns each quarter, and staff can ask for a person to review an allocation.
Treated by
Check AI Input Data; Oversee AI Outputs; Monitor AI Performance and Incidents
Residual risk
medium
Owner
Chief Nursing Officer
Residual risk accepted by
Hospital Board
Accepted on
2026-04-01

AI risk: Surgical decision support

Mapped to 23894-6.4, 23894-6.5, 42001-8.3, 23894-Annex-A, 23894-Annex-B

AI system
Surgical decision support
Human oversight
Human-in-the-loop: a named, competent person reviews each output before it is acted on
Overseen by
Surgeon
Risk
A planning suggestion does not fit the patient's anatomy and misleads the surgical team.
Objectives it bears on
Safety, Robustness
Where it comes from
Technology readiness, Risk sources related to machine learning
Likelihood
unlikely
Consequence
severe
Treatment
The operating surgeon confirms every plan, and suggestions are checked against the imaging at each case review.
Treated by
Oversee AI Outputs; Monitor AI Performance and Incidents
Residual risk
medium
Owner
Chief Medical Officer
Residual risk accepted by
Hospital Board
Accepted on
2026-04-01

Monitoring and review

Mapped to 23894-6.6

The model holds no review field of its own: where a treatment sets a review, its text says so.

This reference model is designed to support conformity with ISO/IEC 42001:2023.

Not legal advice: obligation names are short forms, and the act's text governs. No certification or conformity finding; not affiliated with or endorsed by ISO or IEC. Standard numbers and titles are cited from ISO's public preview.

Document 03-risk-assessmentThis document as JSONsha256: d5bc2d787982980339b46b7fbd82e6a25d3003fe71282311c2f00456f5a4c4ac

Synthetic: an illustrative record, generated from the model of a fictional hospital in a synthetic reference architecture. It holds no customer data and no record of an actual hospital.

AI system impact assessment: Deterioration warning

The impact assessment of the deterioration warning AI system: who it affects, its harms and benefits, and what is done about them.

Scope of the assessment

Mapped to 42005-6.2, 42005-5.5

AI system
Deterioration warning
Assessed on
2026-03-23
Owner
Clinical AI Safety Lead

The AI system

Mapped to 42005-6.3

Purpose
Care-pathway and deterioration warnings
AI Act risk class
high-risk (Art 6(1) and Annex I, as its provider declares it a medical device of class IIa or higher)
The hospital's role
Deployer (AIA Art 3(4)). It becomes the provider of a high-risk system under Art 25(1) if it puts its own name or mark on the system, substantially modifies it, or changes its intended purpose so that it becomes high-risk.
Data-protection roles
Not modelled: the data-protection roles, among them the controller, its processors and the data protection officer (GDPR Art 37), sit outside the AI roles this model holds.
The service it provides
AI service: Deterioration warning
Overseen by
Attending Physician

Data it uses

Mapped to 42005-6.4

  • Patient Record
Data quality
Observations are entered at the bedside and are sometimes late or missing at night; laboratory results arrive complete but after a delay. The training records come from adult general wards only, which is why the assessment rules out its use for children and maternity patients.

Algorithm and model information

Mapped to 42005-6.5

A statistical risk score bought from a supplier, computed from routine observations and laboratory results each time a new value is recorded. The supplier retrains it once a year on the hospital's own records, under the change plan fixed at its conformity assessment, and a new version goes live only after the hospital has validated it on its own recent cases and the clinical safety lead has reviewed the results.

Deployment environment

Mapped to 42005-6.6

The inpatient wards, where nurses record the observations the warning reads and the attending physician reviews each warning before anyone acts on it.

Its service supports:

  • WF-02 Clinical Documentation & Orders

Who it affects

Mapped to 42005-6.7

Adult inpatients on general wards, their families, and the ward nurses and doctors who answer the warnings.

Actual and foreseeable impacts

Mapped to 42005-6.8

Harms
Missed deterioration; alarm fatigue that slows the response to real warnings; extra tests and transfers after false alarms.
Benefits
Earlier recognition of patients who are getting worse, and fewer unplanned transfers to intensive care.
Foreseeable misuse
Treating a quiet score as a reason to skip routine observations, or using it for children or maternity patients it was not built for.

Measures

Mapped to 42005-6.9

From the risk record
Warnings add to routine observations and never replace them; alarm rates and missed events are reviewed every month.

The controls that keep this system's governance record:

  • Keep AI Event Logs
  • Assess and Approve AI Uses
  • Check AI Input Data
  • Monitor AI Performance and Incidents
  • Oversee AI Outputs
  • Assess AI Impact

The controls that keep other AI systems' records but not this one's, as no duty they carry out reaches this system:

  • Inform and Explain AI Use (Explanation of AI-Assisted Decisions (AIA Art 86(1)); Inform Workers Before Use at Work (AIA Art 26(7)); Tell People Subject to AI-Assisted Decisions (AIA Art 26(11)))

Monitoring and review

Mapped to 42005-5.12

Reassess when
Retraining or a change of inputs, use on a new kind of ward, a cluster of missed events, or a year since the last assessment.

This reference model is designed to support conformity with ISO/IEC 42001:2023.

Not legal advice: obligation names are short forms, and the act's text governs. No certification or conformity finding; not affiliated with or endorsed by ISO or IEC. Standard numbers and titles are cited from ISO's public preview.

Document 04-impact-deterioration-warningThis document as JSONsha256: 194411476627233451bfbca47878539675053e1b6341a386f4dbf99f06a298d7

Synthetic: an illustrative record, generated from the model of a fictional hospital in a synthetic reference architecture. It holds no customer data and no record of an actual hospital.

AI system impact assessment: Emergency triage

The impact assessment of the emergency triage AI system: who it affects, its harms and benefits, and what is done about them.

Scope of the assessment

Mapped to 42005-6.2, 42005-5.5

AI system
Emergency triage
Assessed on
2026-03-23
Owner
Clinical AI Safety Lead

The AI system

Mapped to 42005-6.3

Purpose
Emergency patient triage
AI Act risk class
high-risk (Annex III point 5(d), and possibly also Art 6(1) and Annex I if scoring each patient's urgency makes it device software (MDR Art 2(1), Annex VIII Rule 11), a device question the Clinical AI Safety Lead settles with its provider by 2027-06-30)
The hospital's role
Deployer (AIA Art 3(4)). It becomes the provider of a high-risk system under Art 25(1) if it puts its own name or mark on the system, substantially modifies it, or changes its intended purpose so that it becomes high-risk.
Data-protection roles
Not modelled: the data-protection roles, among them the controller, its processors and the data protection officer (GDPR Art 37), sit outside the AI roles this model holds.
The service it provides
AI service: Emergency triage
Overseen by
Registered Nurse

Data it uses

Mapped to 42005-6.4

  • Patient Record
Data quality
Vital signs come from monitors serviced on a fixed schedule. The presenting complaint is typed at arrival and is thin when a patient cannot describe their symptoms. The supplier's training data holds fewer older patients and fewer patients who do not speak the local language, so the hospital's own tests look at those groups apart.

Algorithm and model information

Mapped to 42005-6.5

A supervised classifier bought from a supplier, which scores urgency from the vital signs, age and presenting complaint recorded at arrival. Each version is fixed once the supplier releases it. The supplier describes how it was trained and tested, and the hospital tests each new version on its own recent cases before it goes live.

Deployment environment

Mapped to 42005-6.6

The emergency department, where a triage nurse scores each patient's urgency at arrival. The hospital's process model has no emergency-department triage process of its own yet, so the service is recorded against nurse call response and triage, its nearest process.

Its service supports:

  • Nurse Call Response & Triage

Who it affects

Mapped to 42005-6.7

Patients arriving for emergency care, especially those who cannot describe their symptoms well, and the nurses and doctors who triage them.

Actual and foreseeable impacts

Mapped to 42005-6.8

Harms
Under-triage that delays urgent care; over-triage that crowds out others; accuracy that differs by age, language or disability.
Benefits
A faster and more consistent first assessment at busy times, and earlier attention for the sickest patients.
Foreseeable misuse
Letting the score replace the triage nurse's judgement, or using it to decide whether someone is seen rather than in what order.

Measures

Mapped to 42005-6.9

From the risk record
Triage staff confirm or change every score; under-triage is reviewed weekly for the first three months, then monthly.

The controls that keep this system's governance record:

  • Keep AI Event Logs
  • Assess and Approve AI Uses
  • Check AI Input Data
  • Inform and Explain AI Use
  • Monitor AI Performance and Incidents
  • Oversee AI Outputs
  • Assess AI Impact

Monitoring and review

Mapped to 42005-5.12

Reassess when
A change to the model or its inputs, a new patient group, a rise in under-triage incidents, or a year since the last assessment.

This reference model is designed to support conformity with ISO/IEC 42001:2023.

Not legal advice: obligation names are short forms, and the act's text governs. No certification or conformity finding; not affiliated with or endorsed by ISO or IEC. Standard numbers and titles are cited from ISO's public preview.

Document 05-impact-emergency-triageThis document as JSONsha256: cff83b624d80ed7f3606b8a058a1c6eb6b96ac124bdbc57610f225774b98ab7e

Synthetic: an illustrative record, generated from the model of a fictional hospital in a synthetic reference architecture. It holds no customer data and no record of an actual hospital.

AI management system: internal audit

An internal audit of each of the 8 controls, and 2 follow-up audits: what was checked, what was found and what was done.

Audit summary

Mapped to 42001-9.2

Audit cycle
2026-05-11
Auditor
The hospital's internal audit team, which reports to the hospital board and carries out none of the AI controls it audits.
Controls audited
7 of 8
Not assessed
Keep AI Event Logs (examined by the follow-up audit of 2026-07-13)
Follow-up audits
Assess and Approve AI Uses, 2026-07-13; Keep AI Event Logs, 2026-07-13
ControlAudited onFindingStatus
Assess AI Impact2026-05-11conformingclosed
Assess and Approve AI Uses2026-05-11minor nonconformityclosed
Assess and Approve AI Uses2026-07-13conformingclosed
Check AI Input Data2026-05-11conformingclosed
Inform and Explain AI Use2026-05-11conformingclosed
Keep AI Event Logs2026-05-11not assessedclosed
Keep AI Event Logs2026-07-13conformingclosed
Monitor AI Performance and Incidents2026-05-11observationopen
Oversee AI Outputs2026-05-11conformingclosed
Train Staff in AI Literacy2026-05-11minor nonconformityopen

AI internal audit: Assess AI Impact

Mapped to 42001-9.2

Control
Assess AI Impact
Audited on
2026-05-11
Scope
The data protection and fundamental rights impact assessments of the AI systems in service, and the notices of the fundamental rights assessments' results.
Sample
Six systems: the three assessed for fundamental rights (emergency triage, staff performance monitoring, and staff scheduling and task allocation) and three of the twelve others with a data protection impact assessment (deterioration warning, image analysis and the patient digital assistant).
Criteria
Each AI system that processes personal data has a data protection impact assessment, with the data protection officer's advice, before it goes live; each system the AI Act asks the hospital to assess for fundamental rights has that assessment, and its results were notified.
Finding
conforming
Detail
The assessments of every sampled system were complete, dated before go-live and held the data protection officer's advice, and the three notices had been sent.
Corrective action
None needed.
Status
closed

AI internal audit: Assess and Approve AI Uses

Mapped to 42001-9.2, 42001-10.2

Control
Assess and Approve AI Uses
Audited on
2026-05-11
Scope
The approval, the risk record and the impact assessments of each AI use in service, dated against the use's go-live.
Sample
Five of the 17 uses in service, picked at random: deterioration warning, diagnostic support, staff scheduling and task allocation, the patient digital assistant and clinical note drafting.
Criteria
Every AI use in service has an approval, a risk record and, where one is required, an impact assessment, all in place before go-live.
Finding
minor nonconformity
Detail
One of the five, deterioration warning, went live on 2026-03-12, eleven days before the hospital's own AI system impact assessment of it was signed on 2026-03-23. Its data protection impact assessment was completed on 2026-03-09, before go-live, and as a device system under Art 6(1) it needs no fundamental rights impact assessment (AI Act Art 27(1)).
Corrective action
The go-live checklist now stops on an unsigned impact assessment, and the late case was assessed after the fact; a follow-up audit is to verify that the stop holds.
Due
2026-07-31
Status
closed

AI internal audit: Assess and Approve AI Uses (follow-up)

Mapped to 42001-9.2

Control
Assess and Approve AI Uses
Audited on
2026-07-13
Scope
The go-live stop that the corrective action put in place, on every go-live request made since the audit.
Sample
All four go-live requests made since 2026-05-11, each for a new version of a system in service.
Criteria
Every AI use in service has an approval, a risk record and, where one is required, an impact assessment, all in place before go-live.
Finding
conforming
Detail
The go-live stop held: it stopped two of the four go-live requests made since the audit until their impact assessments were signed, and each of the four went live with its approval, risk record and impact assessments in place.
Corrective action
None needed.
Status
closed

AI internal audit: Check AI Input Data

Mapped to 42001-9.2

Control
Check AI Input Data
Audited on
2026-05-11
Scope
The checks of the records each high-risk AI system reads, made before go-live and after each change.
Sample
Four of the 11 high-risk systems, picked at random: deterioration warning, emergency triage, medication checking, and staff scheduling and task allocation.
Criteria
Before a high-risk AI system goes live and after each change, the records it reads are checked as relevant to its purpose and as representative of the patients or staff it serves.
Finding
conforming
Detail
The input checks of every sampled system were on file, dated before go-live, and compared the system's inputs with the hospital's own recent population.
Corrective action
None needed.
Status
closed

AI internal audit: Inform and Explain AI Use

Mapped to 42001-9.2

Control
Inform and Explain AI Use
Audited on
2026-05-11
Scope
The notices to people affected by an AI-assisted decision, and the answers to their requests for an explanation.
Sample
The notices of every system that supports a decision about a patient or a member of staff, and the three requests for an explanation made since the last audit.
Criteria
People affected by an AI-assisted decision are told that AI was used and can ask for an explanation.
Finding
conforming
Detail
Notices were in place, and the three sampled requests for an explanation were answered in time.
Corrective action
None needed.
Status
closed

AI internal audit: Keep AI Event Logs

Mapped to 42001-9.2

Control
Keep AI Event Logs
Audited on
2026-05-11
Scope
The keeping and the retrieval of the event logs that the high-risk AI systems generate.
Sample
None: no role carried out the control, so there was no one to examine and no log was sampled.
Criteria
The logs that high-risk AI systems generate are kept for the planned period and can be retrieved.
Finding
not assessed
Detail
No role carried out this control at the time: a component ran the log service, and no one was named accountable for the logs, so the audit had no one to examine and sampled no logs.
Corrective action
Name the role accountable for keeping the logs, then audit the control.
Due
2026-07-31
Status
closed

AI internal audit: Keep AI Event Logs (follow-up)

Mapped to 42001-9.2

Control
Keep AI Event Logs
Audited on
2026-07-13
Scope
The keeping and the retrieval of the event logs, now that the health information manager keeps them.
Sample
The last six months of the logs of four high-risk systems, picked at random, and the record of each access to them.
Criteria
The logs that high-risk AI systems generate are kept for the planned period and can be retrieved.
Finding
conforming
Detail
The health information manager now keeps the logs of each high-risk system. The logs of every sampled system were complete for the last six months and could be retrieved, and each access to them was recorded.
Corrective action
None needed.
Status
closed

AI internal audit: Monitor AI Performance and Incidents

Mapped to 42001-9.2

Control
Monitor AI Performance and Incidents
Audited on
2026-05-11
Scope
The monitoring thresholds and drift reports of each AI system, the route of its incidents to the governance committee, and the route of a report outside the hospital.
Sample
Six systems, picked at random, with their drift reports and incident records for the period.
Criteria
Each AI system has monitoring thresholds; breaches and incidents reach the governance committee; and an incident or breach that must be reported outside the hospital reaches the provider and the authorities on time.
Finding
observation
Detail
Every sampled system has thresholds, but two report drift monthly rather than weekly as their monitoring plan says. No serious incident or reportable personal-data breach arose in the period, so no report outside the hospital fell due; the reporting route names the provider, the market surveillance authority and the data protection supervisory authority.
Corrective action
Bring the two reporting cycles in line with their monitoring plans.
Due
2026-07-31
Status
open

AI internal audit: Oversee AI Outputs

Mapped to 42001-9.2

Control
Oversee AI Outputs
Audited on
2026-05-11
Scope
The oversight of each high-risk AI system: who acts on its output, their training and authority, and the record of their overrides.
Sample
Four of the 11 high-risk systems, picked at random, with their overseers and override records.
Criteria
Each high-risk AI system is overseen by the people who act on its output, trained in the system and with the authority to stop or override it, and each override is recorded.
Finding
conforming
Detail
The overseers of every sampled system were named, had finished the system's own training and could stop or override it, and their overrides were recorded. The wider AI-literacy gap has its own audit.
Corrective action
None needed.
Status
closed

AI internal audit: Train Staff in AI Literacy

Mapped to 42001-9.2, 42001-10.2

Control
Train Staff in AI Literacy
Audited on
2026-05-11
Scope
The AI-literacy training of the staff who use an AI system, dated against their first use.
Sample
Fifty users of AI systems, picked at random across the day and night rotas.
Criteria
Staff who use an AI system finish their AI-literacy training before first use.
Finding
minor nonconformity
Detail
Eight percent of sampled users on night rotas had not finished the training.
Corrective action
The training is now part of rota onboarding, and managers receive a monthly list of gaps.
Due
2026-08-31
Status
open

This reference model is designed to support conformity with ISO/IEC 42001:2023.

Not legal advice: obligation names are short forms, and the act's text governs. No certification or conformity finding; not affiliated with or endorsed by ISO or IEC. Standard numbers and titles are cited from ISO's public preview.

Document 06-internal-auditThis document as JSONsha256: 169f9655014908348fe3dfbe370a239e5fca71ca05af7503274d1315e796dac1

Synthetic: an illustrative record, generated from the model of a fictional hospital in a synthetic reference architecture. It holds no customer data and no record of an actual hospital.

AI management system: management review

Top management's review of the management system: its inputs, conclusions and actions.

AI management review

Mapped to 42001-9.3

Owner
Hospital Board
Held on
2026-06-08
Inputs
The internal audit results, the risk register and the impact assessments, the incident and monitoring reports, and progress against the AI objectives.
Conclusions
Of the eight controls audited on 2026-05-11, four were found conforming, two have a minor nonconformity (the late go-live and the training gap), one has an observation (drift reported monthly, not weekly) and one was not assessed (the event logs, which no role kept then); the go-live stop and the training gap need follow-up. One objective was missed once and two were met. The incident objective now names who outside the hospital is told of an AI incident, how soon, and when a system's use is suspended, ahead of the dates the AI Act's duties for high-risk systems apply.
Actions
Name the role accountable for the event logs and audit that control; confirm the go-live stop holds by the next review; close the training gap within a quarter; revisit the incident objective's target after six months of data.

Objectives reviewed

Mapped to 42001-6.2, 42001-9.3

ObjectiveMeasureTargetResult at the review
AI objective: Every high-risk AI system assessedthe share of high-risk AI systems with a current risk record and, where one is required, an impact assessmentall of them before first use, and again at least once a yearMissed once: all 11 high-risk systems hold a current risk record and the impact assessments they need, but 10 of 11 had them before first use; deterioration warning went live on 2026-03-12, before its AI system impact assessment was signed on 2026-03-23.
AI objective: Incidents handled on timethe share of AI incidents triaged within two working days of being reported, and the share of the reports to the provider and the authorities made on timeat least 95 percent triaged each quarter, and every report on time: a serious incident immediately to the provider, then to the importer or distributor and the market surveillance authority, or to that authority within the time limits of AI Act Art 73 if the provider cannot be reached (AI Act Art 26(5)); on a risk that a high-risk AI system presents, the provider or distributor and the market surveillance authority without undue delay, and the system's use suspended (Art 26(5)); and a personal-data breach to the data protection supervisory authority without undue delay, within 72 hours where feasible (GDPR Art 33(1)). For a system that is a device under the medical device regulations, or a device's safety component, the AI Act limits the serious incidents to notify to infringements of the obligations that protect fundamental rights, and they go to the national competent authority that the Member State where the incident occurred chose for that purpose (AI Act Art 73(10))Met for the quarter: each of the nine AI incidents reported was triaged within two working days, and none was a serious incident or a reportable breach, so no report outside the hospital fell due.
AI objective: Staff trained before usethe share of staff using an AI system who finished their AI-literacy training before first useat least 90 percent, rising to all within a yearMet at 94 percent of the staff who use an AI system, above the 90 percent target but short of all; the audit found the gap on night rotas, where 8 percent of the sampled users had not finished the training.

Audits taken as input

Mapped to 42001-9.2, 42001-9.3

AuditAudited onFindingStatus now
AI internal audit: Assess AI Impact2026-05-11conformingclosed
AI internal audit: Assess and Approve AI Uses2026-05-11minor nonconformityclosed
AI internal audit: Check AI Input Data2026-05-11conformingclosed
AI internal audit: Inform and Explain AI Use2026-05-11conformingclosed
AI internal audit: Keep AI Event Logs2026-05-11not assessedclosed
AI internal audit: Monitor AI Performance and Incidents2026-05-11observationopen
AI internal audit: Oversee AI Outputs2026-05-11conformingclosed
AI internal audit: Train Staff in AI Literacy2026-05-11minor nonconformityopen

Held after this review, so not among its inputs:

  • AI internal audit: Assess and Approve AI Uses (follow-up), 2026-07-13: conforming
  • AI internal audit: Keep AI Event Logs (follow-up), 2026-07-13: conforming

This reference model is designed to support conformity with ISO/IEC 42001:2023.

Not legal advice: obligation names are short forms, and the act's text governs. No certification or conformity finding; not affiliated with or endorsed by ISO or IEC. Standard numbers and titles are cited from ISO's public preview.

Document 07-management-reviewThis document as JSONsha256: 240270956ec4c1bff29e3b55f2c3233f3d80bb6bfca0412f192c705b1184c1cc

Synthetic: an illustrative record, generated from the model of a fictional hospital in a synthetic reference architecture. It holds no customer data and no record of an actual hospital.

ISO/IEC 42001:2023 clause-coverage map

Where the model holds each subclause of ISO/IEC 42001:2023 clauses 4 to 10, at both levels the table of contents lists, and why where it does not.

Summary

Subclauses mapped
36: the 24 first-level subclauses of clauses 4 to 10 and the 12 second-level ones under them
Modelled
27
Partly modelled
5
Not modelled
4
Depth
The map follows the standard's table of contents to its deepest level, the second-level subclauses under 6.1, 7.5, 9.2 and 9.3. The table of contents lists nothing below them.

4 Context of the organization

4 of 4 subclauses modelled.

ClauseTitleStatusHow it is modelled, or why notModelled by
4.1Understanding the organization and its contextModelledThe drivers and the binding-law overlay record what shapes the hospital's AI work: the law, the national strategy, patient safety and the risk appetite.EU Binding-Law Overlay; National AI Strategy; Patient Safety; AI Risk Appetite
4.2Understanding the needs and expectations of interested partiesModelledThe stakeholders name the parties with a stake in the AI work. The patient stakeholder lists three groups the hospital serves, but the policy reaches every patient and the staff who use AI, and each impact assessment names the people its AI system affects, families among them.Patients (VIP, Diplomatic, International); Clinicians (Surgeons, Nurses, Pharmacists); Regulators (Health Regulator, Health Ministry, Standards Body); CISO / Compliance Officer; 2 impact assessments; AI policy: Be open with people; AI policy: Equip the people who use AI
4.3Determining the scope of the AI management systemModelledThe scope states where the management system applies, what it leaves out and why, and holds every AI system, the policy and the objectives.AI management system scope
4.4AI management systemModelledThe scope ties the parts together: the controls that run the management system and the committee that approves.AI management system scope; AI Governance Committee; Assess and Approve AI Uses; Assess AI Impact; Monitor AI Performance and Incidents; Oversee AI Outputs; Check AI Input Data; Keep AI Event Logs; Train Staff in AI Literacy; Inform and Explain AI Use

5 Leadership

3 of 3 subclauses modelled.

ClauseTitleStatusHow it is modelled, or why notModelled by
5.1Leadership and commitmentModelledThe hospital board approves each statement of the AI policy and holds the management review; the governance committee, apart from it, fills the approver role that confirms each AI use.Hospital Board; 4 policy principles; the management review; AI Governance Committee; AI Governance Approver
5.2AI policyModelledFour principles state the hospital's intent for AI, and a control process carries out each one.4 policy principles
5.3Roles, responsibilities and authoritiesModelledFour executives own the risk records, the governance roles and the hospital's own roles carry out the controls, and the committee fills the approver role.Chief Medical Officer; Chief Nursing Officer; CFO / COO; CISO / Compliance Officer; AI Governance Approver; AI System Owner; Clinical AI Safety Lead; Data Protection Officer; Fundamental Rights Assessment Lead; Health Information Manager; AI Governance Committee

6 Planning

6 of 7 subclauses modelled, 1 partly.

ClauseTitleStatusHow it is modelled, or why notModelled by
6.1Actions to address risks and opportunitiesModelledEvery AI system has a risk record with its treatment, set against the stated risk appetite, and the risk left after treatment is accepted at the level the appetite sets. Opportunities appear only as the benefits in each impact assessment.17 risk records; AI Risk Appetite; Hospital Board; Chief Medical Officer; Chief Nursing Officer; CFO / COO; CISO / Compliance Officer
6.1.1GeneralModelledThe risk records, their treatments and the impact assessments, set against the stated risk appetite, are the planning for AI risks the model holds.17 risk records; 2 impact assessments; AI Risk Appetite
6.1.2AI risk assessmentModelledThe approval process assesses each AI use before it goes live, and every risk record rates likelihood, consequence and residual risk on the same fixed scales.Assess and Approve AI Uses; 17 risk records
6.1.3AI risk treatmentPartly modelledEach risk record is set to name the treatment chosen, the risk left after it and the executive who owns it. Gap: No statement of applicability is modelled. It would list the Annex A controls, and the public preview this pack was built from lists only A.1 of Annex A, so none is named here.17 risk records; Chief Medical Officer; Chief Nursing Officer; CFO / COO; CISO / Compliance Officer
6.1.4AI system impact assessmentModelledThe approval process assesses a use's effects on people before it goes live; two AI system impact assessments record them for emergency triage and deterioration warning, and data protection and fundamental rights impact assessments record them for the systems that have one.Assess and Approve AI Uses; 2 impact assessments; 15 elements named "Data protection impact assessment: …"; 3 elements named "Fundamental rights impact assessment: …"
6.2AI objectives and planning to achieve themModelledThree objectives, each with a measure, a target and the result the management review found.3 AI objectives
6.3Planning of changesModelledChanges reach the management system as planned transitions: the governance foundation is a plateau, delivered by its work package.Foundation — Security & Governance; Work Package — Security & Governance Hardening Package

7 Support

5 of 8 subclauses modelled, 1 partly.

ClauseTitleStatusHow it is modelled, or why notModelled by
7.1ResourcesNot modelledThe model shows what the AI systems run on and who uses them, not the people, time and budget set aside for the management system itself.—
7.2CompetenceModelledStaff learn what an AI system can and cannot do before they use it, and an objective tracks the share trained before first use.Train Staff in AI Literacy; AI objective: Staff trained before use
7.3AwarenessModelledThe training carries the policy principle that equips the people who use AI.Train Staff in AI Literacy; AI policy: Equip the people who use AI
7.4CommunicationModelledPatients and staff are told when AI plays a part in a decision about them, as the openness principle sets out.Inform and Explain AI Use; AI policy: Be open with people
7.5Documented informationModelledEach AI system and the hospital as a whole have a governance record that the controls write to, and a control process keeps the AI event logs, which a service retains.18 elements named "AI governance record: …"; Keep AI Event Logs; AI Event Log Retention
7.5.1GeneralModelledThe governance records the controls write, and the risk, impact, audit and review records, are the documents the model holds.18 elements named "AI governance record: …"; 17 risk records; 2 impact assessments; 10 internal-audit records; the management review
7.5.2Creating and updating documented informationNot modelledThe model holds each record as it stands on its date, not how a record is drafted, checked or revised.—
7.5.3Control of documented informationPartly modelledA control process is set to keep the AI systems' event logs, which a service retains for their planned period. Gap: How the other records are stored, shared and versioned is not modelled.Keep AI Event Logs; AI Event Log Retention

8 Operation

2 of 4 subclauses modelled, 2 partly.

ClauseTitleStatusHow it is modelled, or why notModelled by
8.1Operational planning and controlModelledEight controls carry the AI work out day to day; each realizes the obligations it answers and writes its records.Assess and Approve AI Uses; Assess AI Impact; Monitor AI Performance and Incidents; Oversee AI Outputs; Check AI Input Data; Keep AI Event Logs; Train Staff in AI Literacy; Inform and Explain AI Use
8.2AI risk assessmentPartly modelledA risk record is set up for each AI system, with its likelihood, consequence and residual risk on fixed scales. Gap: No record holds a date for the next assessment, so when the risks are assessed again is not modelled.17 risk records
8.3AI risk treatmentModelledEach risk record states its treatment and the risk left after it.17 risk records
8.4AI system impact assessmentPartly modelledTwo AI system impact assessments are set to weigh harms, benefits and misuse for the people an AI system affects, data protection and fundamental rights impact assessments are recorded for the systems that have one, and the approval process is set to assess each use before it goes live. Gap: The internal audit of that process found one of five sampled uses live two weeks before its impact assessment was signed; the go-live checklist now stops on an unsigned one.2 impact assessments; 15 elements named "Data protection impact assessment: …"; 3 elements named "Fundamental rights impact assessment: …"; Assess and Approve AI Uses

9 Performance evaluation

6 of 8 subclauses modelled, 1 partly.

ClauseTitleStatusHow it is modelled, or why notModelled by
9.1Monitoring, measurement, analysis and evaluationModelledThe monitoring process watches performance, drift and incidents, and each objective has a measure, a target and a result.Monitor AI Performance and Incidents; 3 AI objectives
9.2Internal auditPartly modelledAn internal-audit record is set up for each control: its auditor, scope, sample, criteria, finding, detail, corrective action, the date that action is due, and status. Gap: No programme of audits is modelled: the records hold one round on one date and two follow-ups, not which audits run, when or how often.10 internal-audit records
9.2.1GeneralModelledEach control's internal-audit record states what the audit set out to check: its criteria.10 internal-audit records
9.2.2Internal audit programmeNot modelledThe model holds one round of audits on one date, each naming its auditor, scope and sample, and two follow-up audits after it; it holds no programme of which audits run, when or how often.—
9.3Management reviewModelledOne management review takes the audits as input and checks each objective.the management review
9.3.1GeneralModelledOne management review, held by the hospital board, looks at the management system as a whole.the management review; Hospital Board
9.3.2Management review inputsModelledThe review records its inputs, takes the internal audits as input and checks each objective.the management review; 10 internal-audit records; 3 AI objectives
9.3.3Management review resultsModelledThe review records its conclusions and the actions it sets.the management review

10 Improvement

1 of 2 subclauses modelled.

ClauseTitleStatusHow it is modelled, or why notModelled by
10.1Continual improvementNot modelledThe model holds one review cycle; improvement shows only across cycles, which a single model state cannot record.—
10.2Nonconformity and corrective actionModelledThe two audits that found a nonconformity record what was found, the corrective action and when it is due; the late go-live's closes only on the follow-up audit that verified the fix, and the training gap stays open.AI internal audit: Assess and Approve AI Uses; AI internal audit: Assess and Approve AI Uses (follow-up); AI internal audit: Train Staff in AI Literacy

Annex A Reference control objectives and controls

Not mapped. The public preview this pack was built from lists only A.1 of Annex A, so the map names no control objective or control from it, and none is inferred.

This reference model is designed to support conformity with ISO/IEC 42001:2023.

Not legal advice: obligation names are short forms, and the act's text governs. No certification or conformity finding; not affiliated with or endorsed by ISO or IEC. Standard numbers and titles are cited from ISO's public preview.

Document 08-clause-mapThis document as JSONsha256: ae9efc531040d6ab5bb95260cfff47e26f4f0d899353e95732f507d307f7fb06

Synthetic: an illustrative record, generated from the model of a fictional hospital in a synthetic reference architecture. It holds no customer data and no record of an actual hospital.

EU obligations and ISO/IEC 42001:2023: crosswalk through the controls

For each EU obligation the model records, the control that realizes it and the ISO/IEC 42001:2023 subclauses whose clause-map entry names that control.

How to read it

Each row is one obligation of the EU binding-law overlay. Where a control in the model realizes it, the row lists the ISO/IEC 42001:2023 subclauses whose entry in the clause map names that control. A row records only that the two are answered by the same control in this model, not that one meets or replaces the other.

The EU obligations here are a selection the model records, not every duty that reaches the hospital. Each applies from the dates its act sets, and many are not yet in application; a high-risk AI system already in service before those dates is reached only if its design changes significantly. In this scenario the hospital is a private body that provides public services, not a public authority, established in an EU Member State the scenario leaves unnamed; rows that turn on national law stay open. "Realizes" is the model's relation: it shows which control the model links to an obligation, not that the obligation is met. Obligation names abbreviate the AI Act as AIA.

Obligations
27
Realized by a control
17
Realized by no control in the model
10

Instruments

InstrumentAs the model cites it
EU AI Act, as AmendedRegulation (EU) 2024/1689 (the AI Act), as amended by Regulation (EU) 2026/1744 (the Digital Omnibus)
EU General Data Protection RegulationRegulation (EU) 2016/679 (the GDPR)
EU Medical Device RegulationRegulation (EU) 2017/745 (the MDR)
EU NIS2 DirectiveDirective (EU) 2022/2555 (NIS2)
European Health Data Space RegulationRegulation (EU) 2025/327 (the EHDS)

Subclauses whose entry names every control

The clause map names every control under these subclauses, so each obligation a control realizes reaches them too. They are listed here once rather than on every row.

  • 4.4 AI management system
  • 8.1 Operational planning and control

Obligations

ObligationControl that realizes itISO/IEC 42001:2023 subclausesThroughWhy none
AI Literacy of Staff (AIA Art 4)Train Staff in AI Literacy7.2 Competence; 7.3 Awarenessvia control—
Competent Human Oversight (AIA Art 26(2))Oversee AI OutputsOnly the subclauses listed abovevia control—
Cooperate with the Competent Authorities (AIA Art 26(12))Monitor AI Performance and Incidents9.1 Monitoring, measurement, analysis and evaluationvia control—
Data Protection Impact Assessment (GDPR Art 35)Assess AI ImpactOnly the subclauses listed abovevia control—
Deployer Transparency for Specific AI Uses (AIA Art 50(3))None in the model——Does not reach this model: no AI use in the model is of a kind it covers.
Disclose AI Interaction, as Provider (AIA Art 50(1))None in the model——Conditional: it reaches the hospital only as the provider of a person-facing AI system; the model counts no use under it.
EHDS Secondary-Use and Record-System Duties (open)None in the model——Open: the duties on health-record systems are not read.
Explanation of AI-Assisted Decisions (AIA Art 86(1))Inform and Explain AI Use7.4 Communicationvia control—
Fundamental-Rights Impact Assessment (AIA Art 27(1))Assess AI ImpactOnly the subclauses listed abovevia control—
Health Data Only Under an Art 9(2) Condition (GDPR Art 9)Assess and Approve AI Uses6.1.2 AI risk assessment; 6.1.4 AI system impact assessment; 8.4 AI system impact assessmentvia control—
In-House Device Exemption Conditions (MDR Art 5(5))None in the model——Conditional: it reaches the hospital only if it builds or modifies a device AI itself; the model counts no use under it.
Inform About Automated Decisions (GDPR Art 13(2)(f))None in the model——Conditional: it reaches coding, billing and claims (review by exception) and the patient digital assistant (sampled review) only if an output is a decision based solely on automated processing with legal or similarly significant effects, and not the clinical, workforce or triage systems, where a person reviews each output before it is acted on; the model counts no use under it.
Inform Workers Before Use at Work (AIA Art 26(7))Inform and Explain AI Use7.4 Communicationvia control—
Keep Logs for at Least Six Months (AIA Art 26(6))Keep AI Event Logs7.5 Documented information; 7.5.3 Control of documented informationvia control—
Lawful Basis for Each Processing Purpose (GDPR Art 6(1))Assess and Approve AI Uses6.1.2 AI risk assessment; 6.1.4 AI system impact assessment; 8.4 AI system impact assessmentvia control—
Monitor, Inform, Suspend and Report (AIA Art 26(5))Monitor AI Performance and Incidents9.1 Monitoring, measurement, analysis and evaluationvia control—
NIS2 Duties Through National Law (open)None in the model——Open: it turns on national law, which the model does not read.
National AI Act Authorities and Channels (open)None in the model——Open: it turns on national law, which the model does not read.
National Health-Data Conditions (open)None in the model——Open: it turns on national law, which the model does not read.
No Prohibited AI Practice (AIA Art 5(1))Assess and Approve AI Uses6.1.2 AI risk assessment; 6.1.4 AI system impact assessment; 8.4 AI system impact assessmentvia control—
No Solely Automated Significant Decision (GDPR Art 22)None in the model——Conditional: it reaches coding, billing and claims (review by exception) and the patient digital assistant (sampled review) only if an output is a decision based solely on automated processing with legal or similarly significant effects, and not the clinical, workforce or triage systems, where a person reviews each output before it is acted on; the model counts no use under it.
Notify the Impact Assessment Results (AIA Art 27(3))Assess AI ImpactOnly the subclauses listed abovevia control—
Register as a Public-Authority Deployer (AIA Art 26(8))None in the model——Does not reach this model: the hospital is a private body that provides public services, not a public authority.
Relevant and Representative Input Data (AIA Art 26(4))Check AI Input DataOnly the subclauses listed abovevia control—
Tell People Subject to AI-Assisted Decisions (AIA Art 26(11))Inform and Explain AI Use7.4 Communicationvia control—
Use Provider Information for the DPIA (AIA Art 26(9))Assess AI ImpactOnly the subclauses listed abovevia control—
Use per the Instructions for Use (AIA Art 26(1))Assess and Approve AI Uses6.1.2 AI risk assessment; 6.1.4 AI system impact assessment; 8.4 AI system impact assessmentvia control—

Annex A Reference control objectives and controls

Not crosswalked. The clause map names no Annex A control objective or control, so no obligation reaches one.